Analog converters: 
EZ-SG:   Strain gauge to DC isolator / converter
EZ102:   Potentiometric to DC isolator / converter
EZ109REG:   Universal converter with galvanic isolation
EZ109REG2:   High performance universal converter
EZ109REG2-H:   High performance universal converter, 85-265 V
EZ109S:   DC current isolator
EZ109UI2:   DC current / voltage converter
EZ110D:   DC current isolator (self-powered) double channel
EZ110S:   DC current isolator (self-powered) single channel

EZ102

Potentiometric to DC isolator / converter


Potentiometric to DC isolator / converter  
EZ102 accepts signal from rheostat (2 wires) or potentiometer (3 wires) and converts/isolates it into mA/V standard signals. The auxiliary power supply allows also an active or passive connections on the output side. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.

Order code :   EZ102
Description:   Potentiometric to DC isolator / converter
Input:   2 wire rheostat, 0..300/500, 0..1000 Ω, 3 wire potentiometer, 200 Ω..1 MΩ
Output:   current 0/4..20 mA; voltage 0/1..5, 0/2..10 V
Precision class:   0,2%
Power supply:   19..40 Vdc, 19..28 Vac
Isolation:   1.500 Vac

EZ109REG

Analog universal converter with galvanic isolation


Analog universal converter with galvanic isolation  
EZ109REG is an universal converter for analog input: voltage, current, thermocouples, PT100, potentiometer. EZ109REG assures sensor powered by 2-wire technique: 20Vcc stabilised, 20mA max with short-circuit protection. The module guarantee measurement and re-transmission on isolated analog output, with voltage and current output. Type of input, zero and span, output mode (zero elevation, scale inversion), output voltage span (5 or 10 V) are settable by DIp-switch. By PC are settable: zero, span, square root extraction, filter, burn-out and other parameters.

Order code :   EZ109REG
Description:   Analog universal converter with galvanic isolation
Input:   bipolar voltage up to 10 Vdc 4 scales, bipolar current up to 20 mA, thermoresistance (Pt100, 2/3 wires, -200..+600°C), thermocouple J,K,R,S,T,B,E,N, potentiometer (500 ohm..1,5 kohm)
Output:   current (0/4..20 mA), voltage (0..5/0..10/1..5/2..10 V)
Precision:   0,2%
Power supply:   19..40 Vdc, 19..28 Vac
Isolation:   1.500 Vac
Programming:   Dip-switch or software (Z-SETUP)

EZ109REG-BP

Universal converter with bipolar mA / V output


Universal converter with bipolar mA / V output  
EZ109REG-BP is a signal converter with universal input: voltage (mV), current (mA), thermocouples TC, thermoresistances RTD, potentiometer, rheostat, NTC. The module offers measurement and re-transmission on isolated analog bipolar output, with voltage output. By DIP-switch are selectable: type of input (start-end), output mode (zero elevation, scale inversion), output voltage type (mA or V). Through mini USB front connector, Z109REG-BP can be programmed by PC: start-end scale, additional input types, square root extraction, filter, burn-out etc.

Order code :   EZ109REG-BP
Description:   Universal converter with bipolar mA / V output
Power Supply:   10..40 Vdc, 19..28 Vac
Power transducer:   Yes, 2-3 wire technique
Isolation:   1.500 Vac at 3 ways
Input:   Nr 1 channel
Output:   Nr 1 bipolar channel (±10 V, ±20 mA)
Settings:   Via software EASY SETUP / mini USB interface or DIP-switches
Operating temperature:   -20 – +65°C

EZ109REG2-H

High performance universal converter, 85-265 V


High performance universal converter, 85-265 V  
EZ109REG2 is an advanced universal converter able to manage all analog signals (mA, V, PT100, Pt1000, Pt500, Ni100, TCs, Ohm) and convert / isolate it into mA/V standard signals. The device can be configured through dip-switches, PC software or handheld device. A digital contact is available as ALARM or STROBE (multiplexing). It can be requested with low or high power supply. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.

Order code :   EZ109REG2-H
Description:   High performance universal converter, 85-265 V
Analog input:   current up to 20 mA, voltage from 75 mV to 20 V, RTD (Pt100, Pt500, Pt1000, Ni100), thermocouple (J, K, R, S, T, B, E, N), potentiometer, rheostat
Analog output:   Current 0..20, 4..20 mA; voltage
Digital I/O:   Strobe Input / Relay output (SPST)
Resolution:   Programmable from 11 bit+sign to 15 bit+sign
Precision class:   0,1%
Response time:   35 ms (@11 bit+sign)
Isolation:   1.500 Vac
Power supply:   85..265 Vac/dc

EZ109S

DC current isolator


DC current isolator  
EZ109S is a device that allows to isolate a mA signals. The device can power also all 2-wire sensors and it can be used to solve also power conflicts into the same mA loop. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.

Order code :   EZ109S
Description:   DC current isolator
Input:   Current 0..20, 4..20 mA, 20Vdc stabilized loop supply, input impedance 20 Ω
Output:   Current 0..20, 4..20 mA
Response Time:   <200 μs, cutoff frequency (-3dB) 6kHz
Precision:   0,2%
Power supply:   9..40 Vdc, 19..28 Vac
Sensors supply:   2 wires, 20 Vdc stabilized, 20 mA max protected against short circuit
Isolation:   1.500 Vac

EZ109S-DI

Wide range Current Loop Isolator


Wide range Current Loop Isolator  
The module EZ109S-DI is a power supply unit with galvanic isolator for the current loop. It converts an input signal into a current in the range 0/4..20mA and makes the measure and retransmission of the signal into an isolated analog output in the range 0/4 - 20 mA. The module can supply a 2-wire sensor with 20 V stabilized voltage and 20 mA maximum current short-circuit protected. The 3-way galvanic isolation reaches 3,500 Vac equivalent to 6.4 kV pulse voltage. Z109S-DI is very useful in energy sector applications.

Order code :   EZ109S-DI
Description:   Wide range Current Loop Isolator
Power Supply:   10..40 Vdc, 19..28 Vac
Input:   0/4..20 mA, 20 Vdc stabilized loop suppyl, input impendance 50 Ω
Output:   Current 0/4..20 mA
Response Time:   < 200 μs, cutoff frequency (-3dB) 6kHz
Isolation:   3.500 Vac at 3 ways
Safety isolation:   < 300 V~ referred to ground CAT II
Pulse Voltage:   6,5 kV
Power transducer:   2-wire technique(max 20 mA)
Dimension:   100x 112 x 18 mm (l x h x w)
Mounting:   DIN rail 46277
Case:   PBT, black

EZ109UI2

DC current / voltage converter


DC current / voltage converter  
EZ109UI2 is a device that accepts mA/V signals able to convert it into mA/V standard signals. It’s configurable either for monopolar or bipolar inputs and all parameters are configurable through dip-switches. The device can power also all 2-wire sensors. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.

Order code :   EZ109UI2
Description:   DC current / voltage converter
Input:   voltage (9 scales, from 100 mV to 20 V), current (bipolar up to 20 mA)
Re-transmitted output:   voltage (0..10 / 2..10 V), current (0..20 / 4..20 mA)
Accuracy:   0,1% (current / voltage input)
Sample frequency / resolution:   from 240 sps (@ 11 bit + sign) up to 15 sps (@ 15 bit + sign)
Power supply:   9..40 Vdc, 19..28 Vac 50-60 Hz
Power transducer:   2 wire, 20 Vdc stabilized, 20 mA max protected against short circuit
Isolation:   1.500 @ 3 way
Settings:   DIP swich or jumper

EZ110D

DC current isolator (self-powered) double channel


DC current isolator (self-powered) double channel  
EZ110 is a 4..20mA isolator powered through the input loop. It does not require any auxiliary power supply. EZ110 is available in two different version: EZ110S (single channel) or EZ110D (double channel). A 2-way galvanic isolation between input // output circuits assures the integrity of your datas.

Order code :   EZ110D
Description:   DC current isolator (self-powered) double channel
Input:   Current 4..20 mA
Output:   Current 4..20 mA
Precision:   0,1%
Power supply:   Self powered on input
Isolation:   1.500 Vac

EZ110S

DC current isolator (self-powered) single channel


DC current isolator (self-powered) single channel  
EZ110 is a 4..20mA isolator powered through the input loop. It does not require any auxiliary power supply. EZ110 is available in two different version: EZ110S (single channel) or EZ110D (double channel). A 2-way galvanic isolation between input // output circuits assures the integrity of your datas.

Order code :   EZ110S
Description:   DC current isolator (self-powered) single channel
Input:   Current 4..20 mA
Output:   Current 4..20 mA
Precision:   0,1%
Power supply:   Self powered on input
Isolation:   1.500 Vac

EZ170REG

DC duplicator / isolator with universal input and 2 output


DC duplicator / isolator with universal input and 2 output  
EZ170REG allows to convert and duplicate an analog signal (mA, V, PT100, Pt1000, Pt500, Ni100, TCs, Ohm) by 2 indipendents outputs (mA or V). It disposes also of dip switches to set the available input/output ranges. The auxiliary power supply allows also an active or passive connections on the output side. A 4-way galvanic isolation among Power supply // input // output1 // output2 circuits assures the integrity of your datas.

Order code :   EZ170REG
Description:   DC duplicator / isolator with universal input and 2 output
Power Supply:   10-40 Vdc; 19..28 Vac
Power Transducer:   Yes, current input (max 17 V)
Isolation:   1,5 kVac
Input:   Nr 1 channel, voltage range (0..10 V), current (0..20 mA) with active/passive connection, potentiometer (1..100 kΩ), thermocouple (J,K,R,S,T,B,E,N), thermoresistance (Pt100, Pt500, Pt1000, Ni100)
Output:   Nr 2 independent channel, voltage range (0..10 V); current (0..20 mA) with active/passive connection
Accuracy:   0,1%
Operating temperature:   -10..+65°C
Dimension (wxhxd):   100 x 112 x 17,5 mm

EZ190

DC adder - subtracter / isolator


DC adder - subtracter / isolator  
EZ190 allows to make the addition or the subtraction of 2 analog signal (mA or V) and get the equivalent output by an analog signal (mA or V). The two inputs can have also different importance. It disposes of dip switches to set the available input/output ranges. The auxiliary power supply allows also an active or passive connections on the output side. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.

Order code :   EZ190
Description:   DC adder - subtracter / isolator
Power supply:   19..40 (9..30 option) Vdc, 19..28 Vac
Isolation:   1.500 Vac
Input:   Nr 2 isolated and independent channels, current 0..20, 4..20 mA; voltage 0..5, 1..5, 0..10, 2..10 V
Output:   Current 0..20, 4..20 mA; voltage 0..5, 1..5, 0..10, 2..10 V
Accuracy:   0,2%

ETAP Users - Listed by Industry Electrical Engineering Consulting Firms ETAP

工程咨询

ETAP Users - Listed by Industry Data Centers ETAP

数据中心

ETAP Users - Listed by Industry Oil & Gas ETAP

采油平台

ETAP Users - Listed by Industry Generation Plants ETAP

发电厂

ETAP Users - Listed by Industry Nuclear Generation ETAP

核电厂

ETAP Users - Listed by Industry Transmission & Distribution ETAP

输配电

ETAP Users - Listed by Industry Government & Military Facilities ETAP

政府及军事设施

ETAP Users - Listed by Industry Metals & Mining ETAP

冶金矿业

ETAP Users - Listed by Industry Manufacturing ETAP

制造业

ETAP Users - Listed by Industry Renewable Energy ETAP

可再生能源

ETAP Users - Listed by Industry Transportation ETAP

铁路运输系统

ETAP Users - Listed by Industry Education - Colleges & Universities ETAP

教育系统