ES Line - Compact / modular Displays:
Scalable display: |
|
4, 6, 8, 4+7 digits |
Universal input: |
|
Analog, Digital, By sensor |
Retransmission output: |
|
Analog or digital |
Power supply extended range: |
|
80-265 Vac; 10-40 Vdc / 19-28 Vac; power transducers |
Accuracy: |
|
0,1% precision class; A/D conversion 14-16 bit |
Alarms (relay): |
|
Hysteresys and threshold control |
Multiple visualization: |
|
Real-time, integrated, totalized measured values |
S311A
Universal analog input indicator - totalizer
ES311A is an universal display with analog input (mA, V, PT100, TCs, Ohm) order codes that allows to view the istantaneous value (engineering units), retransmit it through an isolated analog output and, by the optional board, have N.2 relay alarms and Modbus interface. Furthermore the unit allows to integrate the input and totalize it into the internal memory. It is available with 4,6 or 8 digits and an 7+4 digits (double line).
Order code : |
|
ES311A |
Description: |
|
Universal analog input indicator - totalizer |
Display: |
|
LED 4, 6, 8, 4+7 digit |
Analog universal input: |
|
mA, V, potentiometer, Pt100, TC (J, K, R, S, T, B, E, N) |
Re-transmitted analog output: |
|
mA, V |
Input totalization: |
|
sì |
Dimensions: |
|
96x48x98 mm |
Power supply: |
|
80-265 Vac; 10-40 Vdc / 19-28 Vac |
Sensors supply: |
|
17 V |
Isolation: |
|
1.500 Vac |
Optional boars: |
|
nr 2 SPDT relay alarms, ModBUS RTU interface, reset input |
ES311AK
4 digit display with I/V analog input, high accuracy class
The ES311AK-4-L can read voltage (0-10 V) or current (0-20 mA) signals with or without loop powered measure. All parameters and display configuration can be set by menu. The input will be shown and scaled on 4 digit display according to the setup. S311AK-4-L has an excellent resolution, precision and temperature stability. The compact dimensions allow to improve the assembly in electrical switchboard.
Order code : |
|
ES311AK |
Description: |
|
4 digit display with I/V analog input, high accuracy class |
Accuracy: |
|
0,05% |
A/D converter: |
|
16 bit |
Protection degree: |
|
IP65 |
Thermal drift: |
|
0,005%/°K |
Max power consumption: |
|
< 0,9 W |
Loop power supply: |
|
yes |
Power supply: |
|
10-40 Vdc, 19-28 Vac |
Input type: |
|
mA, V |
Display: |
|
4 digit, LED |
Dimension: |
|
96x48x40 mm |
Programming: |
|
Front key menu |
ES311AK-IP66
4 digit display with I/V analog input, IP66 case
ES311AK is a 4-digit indicator with high-precision analog input: 0.05% maximum error of measurement, 16-bit resolution, thermal stability 0.005% / ° K. It acquires voltage signals (0-10 V) and current (0-20 mA) loop measurement can power (16 V, 25 mA) and is only 40 mm deep. Setting is done via the front menu keys. The version in IP66, electrically isolated, with a transparent front door opening provides high levels of functionality and safety in wet environments, dust, aggressive and extreme temperatures. S311AK-IP66 reduced wiring and installation. It can be integrated into an existing cabinet for the acquisition of an analogue measurement and display in engineering units.
Order code : |
|
ES311AK-IP66 |
Description: |
|
4 digit display with I/V analog input, IP66 case |
High accuracy: |
|
Max error 0,05% |
Max resolution: |
|
16 bit |
Thermal drift: |
|
0,005%/°K |
Analog input range: |
|
Volage 0-10 V or current 0-20 mA, free setting (1-5 V, 4-20 mA, etc.) |
Loop power supply: |
|
16 V, 25 mA |
Power supply: |
|
10-40 Vdc, 19-28 Vac |
Case: |
|
ABS, IP66, 130 x 80 x 60 mm |
Standard: |
|
EN 50298, EN 60529, EN 62262, UL 94 HB, NEMA 1, 4, 4X, 6 |
ES311D
Frequency / digital input indicator - totalizer
ES311D is an indicator totalizer that accetpts universal opto isolated digital input. Admitted signal types are reed, npn (2 wires or 24 V), pnp (24 V), NAMUR, photoelectric, Hall, 24 V input, TTL, variable reluctance. Digital input signal frequency measurement starts from 0.00015 Hz to 10 kHz. ES311D supports increment or decrement totalizing of the digital input signal. Also it's possibile viewing the frequency measurement and/or totalized value. Programmable retransmission of the input value frequency is possibile by the isolated analog output (voltage or active/passive current). Retransmission of the totalized value by the isolated digital output (Open Collector). Totalizer value is saved on non-volatile memory.
Order code : |
|
ES311D |
Description: |
|
Frequency / digital input indicator - totalizer |
Display: |
|
LED 4, 6, 8, 4+7 digit |
Input: |
|
contact, npn, pnp, namur, photoelectric, variable reluctance, 24 V pulses, TTL |
Re-transmitted analog output: |
|
mA, V |
Input totalization: |
|
yes |
Dimensions: |
|
96x48x98 mm |
Power supply: |
|
80-265 Vac; 10-40 Vdc / 19-28 Vac |
Sensors supply: |
|
17 V |
Isolation: |
|
1.500 Vac |
Optional board: |
|
nr 2 SPDT relay alarms, ModBUS RTU interface, reset input |
ES311OPZ
ES311A / ES311D optional board
Optional board with RS485 Modbus interface, 2-CH alarm relay, 1-CH digital input. Available for ES311A and ES311D digital displays.
Order code : |
|
ES311OPZ |
Description: |
|
ES311A / ES311D optional board |
ES312A
Analog Indicator 4-Digits Display with 4 relay outputs
ES312A is a Modbus digital indicator with universal input in voltage, current, thermocouples,, thermoresistors (2, 3 or 4 wires measurements), potentiometer. The instrument allows programmable retransmission of the measured instantaneous value by the isolated analog output (voltage or active/passive current). S312A is provided of programmable filter at 20 levels to stabilise reading. Four alarms are activable on the instantaneous input value (alarm type: maximum, minimum, automatically resettable or not). Alarms status is visible through four leds on the frontal panel.
Order code : |
|
ES312A |
Description: |
|
Analog Indicator 4-Digits Display with 4 relay outputs |
Display: |
|
4 digit LED |
Analog Input: |
|
Nr1-CH voltage (0..+10 V), current (0..20 mA), thermocouple (J,K,R,S,T,B,E,N), Pt100 2,3,4 wire (-150..+650°C), potentiometer(1..100KOhm) |
Analog Output: |
|
Nr1-CH (0..10 V, 0..20 mA) [retransmission] |
Digital Input: |
|
Nr1-CH isolated (10-30 V) [reset] |
Digital Output: |
|
Nr 4-CH relay , 5 A / 250 Vac [alarm] |
Communication: |
|
RS485 interface, ModBUS RTU |
Settings: |
|
Front keys, Jumper, PC software |
ES315
4 digit loop powered display with 4-20 mA input signal
ES315, the new indicator of the compact S-Series, is a loop powered, high-performance digital display. The maximum error is only 0.005% with up to 16 bits. ES315 stands a measurement loop of the active device (Vmax = 30 V), which must be greater than the maximum voltage across the voltage drop (7V). Programming is possible via the front menu keys. Access can be controlled via passwords. S315 acquires signals 4-20 mA current. All parameters of the con-figuration and display can be set to any menu with access protected by password.
Order code : |
|
ES315 |
Description: |
|
4 digit loop powered display with 4-20 mA input signal |
Accuracy: |
|
0,05% |
Max resolution: |
|
16 bit |
Thermal drift: |
|
0,005%/°K |
Analog input: |
|
Current 4-20 mA |
Power supply: |
|
By loop circuit (max 30 V) |
Max drop voltage: |
|
7 V |
Programming: |
|
Front key menu, protection by password |
Compact dimension: |
|
96 x 48 x 40 mm [l x h x d] |
Operating temperature: |
|
-10..+65°C |
ES315-IP66
4 digit loop powered display with 4-20 mA input signal and IP66 case
ES315, the new indicator of the compact S-Series, is a loop powered, high-performance measurement. The version in IP66, electrically isolated, with a transparent front door opening provides high levels of functionality and safety in wet, dusty, aggressive and extreme temperatures. S315/IP66 reduce wiring and ensures easy installation in any position with external screws, cable included, no need to be integrated into a cabinet. It can be integrated into an existing facility for the acquisition of an analogue measurement and display in engineering units.
Order code : |
|
ES315-IP66 |
Description: |
|
4 digit loop powered display with 4-20 mA input signal and IP66 case |
Accuracy: |
|
Max error 0,05% |
Resolution: |
|
Max 16 bit |
Thermal drift: |
|
0,005%/°K |
Analog input: |
|
Current 4-20 mA |
Power supply: |
|
By loop (max 30 V) |
Voltage drop voltage: |
|
Max 7 V |
Case: |
|
ABS, IP66, 130 x 80 x 60 mm |
Standard: |
|
EN 50298, EN 60529, EN 62262, UL 94 HB, NEMA 1, 4, 4X, 6 |