EK400CL

Surge protection for analog signals and logical, slim format 6.2mm


Surge protection for analog signals and logical, slim format 6.2mm  
EK400CL is a surge protection for measuring, control and regulation devices. It can be used in binary and analog circuits such as pulse signals 0-10 Vdc and current loop 0/4..20mA.

Order code :   EK400CL
Description:   Surge protection for analog signals and logical, slim format 6.2mm
IEC category / EN type:   C1, C2, C3, D1
Rated surge arrester voltage UC:   25 VAC / 36 VDC
Lightning test current Iimp (10/350)μs:   500 A
Nominal current IN:   350 mA (40°C)
Nominal discharge current In (8/20)μs:   10 kA
Residual surge current (8/20)μs Line - ground:   20 kA
Output voltage limitatin at 1 kV/μs - Line-line/line-ground:   ≤ 60 V / ≤ 650 V
Max. back-up fuse (in acc. with IEC 127-2/III):   315 mA
Resistance per path:   3,3 Ω ± 20%
Temperature range:   -40 °C ... 80 °C
Degree of protection in acc. with CEI/EN 60539:   IP 20
Inflammability class in acc. with UL94:   V0
Test standards:   DIN EN 61643-21
Connection data (Solid / stranded / AWG ):   0,2-2,5 mm2 / 0,2-2,5 mm2 / 24-14
Thread:   M 3
Torque:   0,8 Nm
Stripping length:   8 mm
Contamination class:   2
Surge voltage category:   III
Max. input voltage Ui / Uo:   36 V DC
Max.input current Ii / Io:   T6
Max. internal capacitance Ci / Co:   1,3 nF
Max. inner inductance Li / Lo:   1 μH
Max. inner power Pi / Po:   3 W
Maximum inner time factor t (Ri/Li):   0,2 μs

ES400CL-1

Overvoltage protection for analog signals and logical with disconnector


Overvoltage protection for analog signals and logical with disconnector  
ES400CL-1 is a surge protection for measuring, control and regulation devices. The device is equipped with terminal blocks with protection multistage, screw connections and one disconnector. S400CL-1 can be used in binary and analog circuits such as pulse signals 0-10Vdc and current loop 0/4..20mA.

Order code :   ES400CL-1
Description:   Overvoltage protection for analog signals and logical with disconnector
IEC category / VDE requirement class:   C1, C2, C3, D1
Max. perm. operating voltage UC:   30 VDC / 21 VAC
Lightning test current Iimp (10/350) μs - Core - ground:   500 A
Nominal current IN:   300 mA (40 °C)
Backup fuse max.:   315 mA
Nominal discharge surge current In (8/20) μs - Core – core / core - ground:   5 kA / 5 kA
Total surge current (8/20) μs - Core – ground:   10 kA
Output voltage threshold at 1 kV / μs - Core – core / core – ground:   ≤ 45 V / ≤ 650 V
Residual voltage at In core - core:   ≤ 45 V
Protection level UP C2 ( 10kV / 5 kA ) - Core – core / core – ground:   ≤ 55 V / ≤ 650 V
Response time TA Core – core / core - ground:   ≤ 1 ns / ≤ 100 ns
Cut-off frequency (3dB) symmetrical in a 150 Ω system:   typ. 2 MHz
Resistance per path:   3,3 Ù ±20%
Temperature range:   -40 °C…+85 °C
Inflammability class according to UL 94:   V0
Degree of protection with IEC 60529 / EN 60529:   IP20
Test standards:   IEC 61 643-21
Connection data (solid / stranded / AWG):   0,2 mm² - 2,5 mm² / 0,2 mm² - 2,5 mm² / 24-12
Screw thread / tightening torque:   M3 / 0,6 Nm
Stripping length:   8 mm
Surge voltage category:   III
Pollution degree:   2

ES400ETH-DSK

Surge protection for Ethernet networks Class.D / Cat.5-5e, 1Gbit / s PoE


Surge protection for Ethernet networks Class.D / Cat.5-5e, 1Gbit / s PoE  
ES400ETH - DSK is a surge protection for Ethernet / Profinet cabling with twisted pair. Suitable for LAN interfaces (Classe D/ Cat.5-5e with Cat.6 cables) networks with data transmission rates up to secure 1 Gbit/s. Token Ring, ISDN, DS1, Ethernet and Power over Ethernet (PoE) "A mode" and "B mode", the device includes a protection adapter for eight signal paths via RJ45 connectors.

Order code :   ES400ETH-DSK
Description:   Surge protection for Ethernet networks Class.D / Cat.5-5e, 1Gbit / s PoE
IEC test classification:   B2 / C1
Maximum continuous operating voltage UC:   ≤ 5 V DC
Nominal current IN:   ≤ 1,5 A (25 °C)
Nominal discharge current In (8/20) μs - Core-Core / Core-Ground:   350 A / 350 A
Voltage protection level UP - Core-Core / Core-Ground:   ≤ 20 V (B2 - 1 kV / 25 A) / ≤ 700 V (B2 - 1 kV / 25 A)
Ambient temperature (operation):   -40 °C ... 85 °C
Degree of protection:   IP 20
Test standards:   EC 61643-21/A1/ GB/T 18802.21 / EN 61643-21/A1

ES400HV-2

Type 2 surge arrester for power lines


 
ES400HV-2 is a multi-pole surge arrester, Type 2 universal plug-in system for 3 conductors (L, N, PE), power class 30/40 kA, Imax 40 kA, Uc 335 Vac, disconnecting device on each individual connector, visual indication of status (mechanical), individual unloaders, mechanical coding of all slots.

Order code :   ES400HV-2
Description:   Type 2 surge arrester for power lines
IEC category / EN type:   II , T2 / T2
Number of ports:   1
Nominal voltage UN AC:   240/415 VAC (TN-S) / 240/415 V AC (TT)
Maximum continuous operating voltage UC - L-N / N-PE:   335 V AC / 260 V AC
Residual current IPE:   <= 5 μA
Short-circuit current rating ISCCR:   25 kA
Follow current interrupt rating Ifi - N-PE:   100 A (260 V)
Max. discharge surge current Imax (8/20)μs - L-N / N-PE:   40 kA / 40 kA
Voltage protection level UP L-N / N-PE:   ≤ 1,5 kV / 1,5 kV
Nominal discharge surge current In (8/20)μs - L-N / N-PE:   20 kA / 20 kA
Max. required backup fuse with branch wiring:   125 A AC (gG)
Max. required backup fuse with V-type through wiring:   80 A AC (gG)
Ambient temperature (operation):   -40 °C ... 80 °C
Permissible humidity (operation):   5 % ... 95 %
Degree of protection:   IP 20

S400LV-1

Type 3 Surge protection device 24 Vac / dc, with contact intervention, 3 conductors (L, N, PE)


 
S400LV-1 is a type 3 surge protection device for 24 Vac / dc power lines. It consists of plug and base, with contact intervention and visual intervention. The device is available for any 3 conductors (L, N, PE).

Order code :   S400LV-1
Description:   Type 3 Surge protection device 24 Vac / dc, with contact intervention, 3 conductors (L, N, PE)
Test classification // EN type:   III / T3
Number of ports:   One
Nominal voltage UN:   24 V AC (TN-S)
Nominal frequency:   50 Hz (60 Hz)
Maximum continuous operating voltage UC:   34 V AC / 34 V DC
Combination wave UOC:   2 kV
Protection level UP - L-N / L-PE / N-PE:   ≤ 0,18 kV / ≤ 0,55 kV / ≤ 0,55 kV
Residual current IPE:   ≤ 5 μA
Nominal discharge current In (8/20) μs:   1 kA
Short-circuit current rating ISCCR:   1,5 kA AC / 1 kA DC
Rated load current IL at 63 °C:   16 A AC
Max. backup fuse with branch wiring:   16 A AC (B) / 10 A DC (gG) / 10 A DC (B)
Maximum backup fuse for through wiring:   16 A AC (B) / 10 A DC (gG) / 10 A DC (B)
Ambient temperature (operation):   -40 °C ... 80 °C
Degree of protection:   IP20

ES400NET

Surge protection for Ethernet , serial and fieldbus , 5 wires


 
ES400NET is a surge protection for networks up to 5 signal wires. The device is designed for very high transmission speeds and capacity dispersion. It supports bus interfaces such as RS232/422/485, Interbus, Profibus and Ethernet.

Order code :   ES400NET
Description:   Surge protection for Ethernet , serial and fieldbus , 5 wires
IEC test classification:   C1,C2,C3,D1
Nominal voltage IN:   5 V DC
Maximum continuous operating voltage UC:   3,6 V AC/5,2 V DC
Nominal current IN:   450 mA (45 °C)
Impulse discharge current Iimp (10/350)μs per path:   2,5 kA
Nominal discharge current In (8/20)μs - Core-Core / Core-Ground:   10 kA / 10 kA
Total surge current (8/20)μs. 20 kA
Voltage protection level UP - Core-Core / Core-Ground:   ≤ 45V (C3 - 25 A) / ≤ 45 V (C3 - 25 A)
Output voltage limitation at 1 kV/μs, static - Core-Core / Core-Ground:   ≤ 15 V/≤ 15 V
Resistance in series:   2,2 Ω ±10 %
Max. required back-up fuse:   500 mA
Ambient temperature (operation):   -40 °C ... 85 °C
Degree of protection:   Ip20
Inflammability class according to UL 94:   V0
Pollution degree:   2
Surge voltage category:   III
Test standards:   IEC 61643-21/A1 / EN 61643-21/A1

ETAP Users - Listed by Industry Electrical Engineering Consulting Firms ETAP

工程咨询

ETAP Users - Listed by Industry Data Centers ETAP

数据中心

ETAP Users - Listed by Industry Oil & Gas ETAP

采油平台

ETAP Users - Listed by Industry Generation Plants ETAP

发电厂

ETAP Users - Listed by Industry Nuclear Generation ETAP

核电厂

ETAP Users - Listed by Industry Transmission & Distribution ETAP

输配电

ETAP Users - Listed by Industry Government & Military Facilities ETAP

政府及军事设施

ETAP Users - Listed by Industry Metals & Mining ETAP

冶金矿业

ETAP Users - Listed by Industry Manufacturing ETAP

制造业

ETAP Users - Listed by Industry Renewable Energy ETAP

可再生能源

ETAP Users - Listed by Industry Transportation ETAP

铁路运输系统

ETAP Users - Listed by Industry Education - Colleges & Universities ETAP

教育系统