Temperature converters:
EZ109PT2: |
|
RTD to DC current / voltage isolator converter |
EZ109TC: |
|
Thermocouple to DC isolator / converter |
Z109PT2
RTD to DC current / voltage isolator converter
EZ109PT2 is a converter for Thermoresistance RTD (PT100, PT1000, PT500, Nì100) with 2,3,4 wires and provides a mA/V standard output signal. It’s completely configurable through dip switches and software. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.
Order code : |
|
EZ109PT2 |
Description: |
|
RTD to DC current / voltage isolator converter |
Power supply: |
|
9..40 Vdc, 19-28 Vac 50-60 Hz |
Isolation: |
|
1.500 @ 3 way |
Input: |
|
RTD (Ni100, Pt100, Pt500, Pt1000, Ni100) |
Output: |
|
Voltage (0..5 / 0..10 / 1..5 / 2..10 V), current (0..20 / 4..20 mA) |
Accuracy: |
|
0,1% |
Sample frequency / Resolution: |
|
From 240 sps (@ 11 bit + sign) to 15 sps (@ 15 bit + sign) |
Settings: |
|
Via DIP switch (input / output type, start - end, measure range), or jumper (active / passive output) |
EZ109TC2
Thermocouple to DC isolator / converter
EZ109TC2 is a converter for Thermocouples TCs (J,K, E, N, S, R, B, T) and provides a mA/V standard output signal. It’s completely configurable through dip switches. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.
Order code : |
|
EZ109TC2 |
Description: |
|
Thermocouple to DC isolator / converter |
Power supply: |
|
10..40 Vdc / 19..28 Vac / 50-60 Hz |
Power consumption: |
|
2 W |
Isolation: |
|
1.500 Vac (3 way) |
Power transducers: |
|
Yes |
Status Indicators: |
|
Power supply, error, data transm., data reception, input status |
Accuracy: |
|
0,1% |
Response time: |
|
35 ms con risoluzione ad 11bit and 140 ms con risoluzione 16bit |
Mounting: |
|
35 mm DIN rail guide |
Protection Degree: |
|
IP20 |