Digital meters modular DIN
There are 90 products.
 Code Description Model Tech. Note Manual Stock  
DGMA01A3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 24 Vac - Visualiz: direct 9,99 A

DGM D4      
DGMA01A4

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 24 Vac - Visualiz: direct 20,0 A

DGM D4      
DGMA03A3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 115 Vac - Visualiz: direct 9,99 A

DGM D4      
DGMA03A4

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 115 Vac - Visualiz: direct 20,0 A

DGM D4      
DGMA06A3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 230 Vac - Visualiz: direct 9,99 A

DGM D4      
DGMA06A4

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 230 Vac - Visualiz: direct 20,0 A

DGM D4      
DGMA07A3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 240 Vac - Visualiz: direct 9,99 A

DGM D4      
DGMA07A4

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 240 Vac - Visualiz: direct 20,0 A

DGM D4      
DGMA0HA3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 20...150 Vdc/48 Vac - Visualiz: direct 9,99 A

DGM D4      
DGMA0HA4

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 20...150 Vdc/48 Vac - Visualiz: direct 20,0 A

DGM D4      
DGMA0LA3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 10 A - Aux: 150...250 Vdc - Visualiz: direct 9,99 A

DGM D4      
DGMA0LA4

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 20 A - Aux: 150...250 Vdc - Visualiz: direct 20,0 A

DGM D4      
DGMA21A3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 24 Vac - Visualiz: direct 9,99 A

DGM D4    
DGMA23A3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 115 Vac - Visualiz: direct 9,99 A

DGM D4    
DGMA26A3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 230 Vac - Visualiz: direct 9,99 A

DGM D4    
DGMA27A3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 240 Vac - Visualiz: direct 9,99 A

DGM D4    
DGMA2HA3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 20...150 Vdc/48 Vac - Visualiz: direct 9,99 A

DGM D4    
DGMA2LA3

RMS alternating current (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 10 A - Aux: 150...250 Vdc - Visualiz: direct 9,99 A

DGM D4    
DGMD01D1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 24 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD03D1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 115 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD06D1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 230 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD07D1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 240 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD0HD1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD0LD1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 100 V - Aux: 150...250 Vdc - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD21D1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 24 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD23D1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 115 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD26D1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 230 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD27D1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 240 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD2HD1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    
DGMD2LD1

RMS alternating voltage (input from VT) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 100 V - Aux: 150...250 Vdc - Visualiz: 100 V…250 kV (43 selectable ranges)

DGM D4    

Code
  Description Model Tech. Note Manual Stock  
DGMG01C1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG01C2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG03C1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG03C2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG06C1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG06C2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG07C1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG07C2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG0HC1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG0HC2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG0LC1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 5 A o 500 V - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG0LC2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 1 A o 500 V - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG21C1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG21C2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG23C1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG23C2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG26C1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG26C2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG27C1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG27C2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG2HC1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG2HC2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG2LC1

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 5 A o 500 V - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMG2LC2

Current (input from CT) or RMS alternating voltage (direct input) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 1 A o 500 V - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)/direct 500 V

DGM D4    
DGMM01L4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM03L4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM06L4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM07L4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM0HL4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM0LL4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: no alarm - Input: 60/100/150 mV selectable - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
Code
  Description Model Tech. Note Manual Stock  
DGMM21L4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 24 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM23L4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 115 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM26L4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 230 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM27L4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 240 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM2HL4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 20...150 Vdc/48 Vac - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
DGMM2LL4

Unidirectional direct current (input from shunt) 1000 points - Format: 4 DIN module - Alarm threshold: programmable 2 max or 2 min or 1 min + 1 max - Input: 60/100/150 mV selectable - Aux: 150...250 Vdc - Visualiz: 5…8000 A (38 selectable ranges)

DGM D4    
ETAP Users - Listed by Industry Electrical Engineering Consulting Firms ETAP

工程咨询

ETAP Users - Listed by Industry Data Centers ETAP

数据中心

ETAP Users - Listed by Industry Oil & Gas ETAP

采油平台

ETAP Users - Listed by Industry Generation Plants ETAP

发电厂

ETAP Users - Listed by Industry Nuclear Generation ETAP

核电厂

ETAP Users - Listed by Industry Transmission & Distribution ETAP

输配电

ETAP Users - Listed by Industry Government & Military Facilities ETAP

政府及军事设施

ETAP Users - Listed by Industry Metals & Mining ETAP

冶金矿业

ETAP Users - Listed by Industry Manufacturing ETAP

制造业

ETAP Users - Listed by Industry Renewable Energy ETAP

可再生能源

ETAP Users - Listed by Industry Transportation ETAP

铁路运输系统

ETAP Users - Listed by Industry Education - Colleges & Universities ETAP

教育系统