收藏 设为首页 搜索

温度变送器DE62T45300    订购编号:

点击这里发送询价

请详细填写一下内容,包括产品原产国、品牌完整名称以及您所能得到的所有信息,这将有助于我们准确迅速的报价。非常感谢!

品牌厂商(Manutacturer)*

公司名称*

产品名称(Product Name)*

联系人*

产品型号(Product Type)*

联系地址*

产品序列号(ID-Nr;Artikel-Nr)

联系电话*

产品描述(Voltage,Amp,Kw,Rpm)

传真*

需求数量(Quantity demanded)

联系邮箱*

附加信息,更具体要求

Temperature Transmitter DE62T 45300

<p>Temperatur-Messumformer D62T 45300<br />Temperature Transmitter D62T 45300</p>

for Pt, Ni and TC Standard-Sensors, programmable per USB and DIP switch

The Temperature Transmitter DE62T 45300 converts the sensor signal on input to temperature linear standard signal 0/4 to 20 mA or 0 to 5/10 V.

  • Universal Temperature Measuring Input
    for Platinum, Nickel and Thermocouple Standard Sensors
  • Easy configurable per USB or DIP switch
    Sensor type, measuring range, sensor connection und output signal easy programmable per USB interface - without supply power - or calibrated range selection per DIP switch
  • 3-port isolation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design
    6.2 mm thin housing for DIN rail mounting
  • Cross-connector for the auxiliary power supply
    fast and economical installation
  • Protective Separation acc. to EN 61140
    Protects service personnel and downstream devices against impermissibly high voltage
  • Maximum reliability
    No maintenance costs
  • 5 Years Warranty
    Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)

The Temperature Transmitter DE62T 45300 converts the sensor signal on input to temperature linear standard signal 0/4 to 20 mA or 0 to 5/10 V.

Due to the easy configuration via USB interface and the calibrated range selection per DIP switch the Transmitter is suitable for flexible use. The high reliability and the protective separation are further features, which ensure a safe system operation.

With the USB Programming-Kit DRAGOset the Transmitter can be configured and all data can be stored by a PC. In mode of programming no additionally auxiliary power is required.

Pluggable cross-connectors for the auxiliary power supply ensure fast and economical installation. The slim housing with 6.2 mm wide saves significant space on DIN-rail in the switch cabinet.

The optimized efficiency of the DE62T 45300 power pack contributes a significant reduction of the unit’s own heat generation. This is reflected in extremely high MTBF, which means highest reliability and long-term stability. A green LED on the front of the unit has been provided to monitor the power supply. The status of power supply and sensor connection will be displayed by a LED on front.

Technical Data

Input

Resistance Thermometer Sensor Measuring range min. Span
    Pt 100 -200 °C to +850 °C 50 K
    Pt 1000 -200 °C to +850 °C 50 K
    Ni 100 -50 °C to +175 °C 50 K
  Measuring error max. < 0.1 K / 0.05 %
  Temperature influence < 50 ppm/K
  Sensor connection 4-wire, 3-wire, 2-wire
  Cable resistance < 100 Ohm per wire
  Sensor current 0.2 mA
  Diagnostic function Sensor / wire break, Error signal on output programmable
Thermocouples Sensor Measuring range min. Span
    Type J -200 °C to +1200 °C 50 K
    Type K -200 °C to +1375 °C 50 K
  Measuring error max. < 0.3 K / 0.1 %
  Temperature influence < 50 ppm/K
  Cold junction compensation internal, external, uncompensated
  Error of Cold junction, internal < 1.5 K
  Diagnostic function Sensor / wire break, Error signal on output programmable

Output

  Current Voltage
Output signal 0 to 20 mA, 4 to 20 mA 0 to 5 V, 0 to 10 V
Load ≤ 12 V     (600 Ohm @ 20 mA) ≤ 5 mA     (2 kOhm @ 10 V)
Offset < 20 µA < 10 mV
Linear transfer range 0 to 102.5 % FSR
(3.8 to 20.5 mA at Output 4 to 20 mA)
Error signal 0 % / 110 % of output range, programmable
Residual ripple < 10 mVrms

General Data

Transfer characteristic Rising / falling linearly
Transmission error < 0.1 %
Temperature coefficient 1) < 100 ppm/K full scale
Measurement rate 4 / s
Test voltage 2.5 kV, 50 Hz Input against output against power supply
Working voltage 2)
(basic insulation)
600 V AC/DC for overvoltage category II and contamination class 2 acc. to EN 61010 part 1
Protection against
electric shocke 2)
Protective Separation by reinforced insulation acc. to EN 61010 part 1 up to 300 V AC/DC for overvoltage category II and contamination class 2 between input and output and power supply.
Ambient temperature Operation
Transport and storage
-25 °C to +70 °C
-40 °C to +85 °C
(-13 to +158 °F)
(-40 to +185 °F)
Power supply 24 V DC 16.8 V to 31.2 V DC, approx. 0.8 W
EMC 3) EN 61326-1
Construction 6.2 mm housing, protection type: IP 20
Weight approx. 50 g
  1. Average TC in specified operating temperature range
  2. As far as practicable the standards and rules mentioned above are considered by development and production of our devices. In addition the assembly rules for our devices are to be considered by installation in other equipments. For applications with high working voltages, take measures to prevent accidental contact and make sure that there is sufficient distance or insulation between adjacent situated devices.
  3. Minor deviations possible during interference
Boldface: Factory setting:
Input Pt100, 0 to 100 °C, 4-wire, Output 0 to 20 mA, transfer characteristic rising, error signal 22 mA

Block diagram

D62t45300

Dimensions

Gehaeuseform6-2mm

Terminal assignments
Screw terminals, wire cross-section max. 1.5 mm²

1 Input     5 Output +
2 Input 6 Output -
3 Input 7 Power +
4 Input 8 Power -

Product line

Item Order No.
Temperature Transmitter DE62T 45300
 
Accessory
 
DRAGOset USB Programming Cable and Software DEZU 1201
Cross connector 8-poles (2 pieces, red/blue)
for looping through the power supply for up to 8 units
 
DEZU 1205
广泛运用于石油、化工、冶金、天然气、制药、煤矿、船舶、建材等行业